| Information Name: | Supply Olympus microscope CX21 (teaching microscopes) |
| Published: | 2012-06-04 |
| Validity: | 30 |
| Specifications: | |
| Quantity: | 100.00 |
| Price Description: | |
| Detailed Product Description: | On Haipu He photoelectric - focus on the microscopic optical! [(Liao Zemin) 13,916,956,665
Address: Room 1202, Minhang District, Shanghai, China Xinsong Road 958, Lane Big Wave Bay Road on the 12th
The Puch photoelectric (Shanghai) Co., Ltd. (hereinafter referred to: Puch photoelectric) is one of the country's largest import equipment and special lighting suppliers, all year round provided the original Japanese (Japan) imports (Olympus) Olympus microscope instructions for use and precautions
1, the mirror can be used as a bright-field microscope can also be used as a fluorescence microscope, as needed, the corresponding attachment connection, open the corresponding power. Against chaos tune the settings, so as not to affect others' normal use. 2, used as a bright field microscope; A, power, open the power switch in front of the microscope base, bright need to adjust the base of the right of the slider. B, according to the needs of adjusting the base grating and the grating and its height of the condenser, to obtain the best image effect. C, you need to picture, should mirror the rod pulled the seat of the Green Line. Press the camera button on the corresponding attachment. Used as a fluorescence microscope; turn off the fluorescent channel, and then open the fluorescence excitation power supply, wait 15 minutes. The waiting period to open the microscope light source, find the need to observe the sample, the appropriate choice of the objective lens to adjust the focus. C, turn off the microscope light source, open the fluorescent channel. , Needs pictures, the lens body should be on the rod pulled the seat of the Green Line. Press the camera button on the corresponding attachment. 4, first observed at low magnification, focusing first coarse, fine-tuning, if necessary, then high magnification, just fine-tuning; For taking pictures, turn on the computer, click the Desktop Image-Pro Plus Demo "shortcut way to start the shoot system; select the Scan command in the Acquire menu, select black and white or color shooting mode, adjust the parameters of the exposure time, gain, color saturation, and a satisfactory image, select "Picking" command; select the Calibration menu of the Select Spatial, command to add the ruler; save the image; 5, turn off the shooting system, turn off the power to cast eyepiece protective sleeve;
Compact design for easy storage and handling of only 391mm high (Puch photoelectric) CX21 microscope, compact enough to fit into an ordinary classroom closet. Cable bracket and wood storage box as an optional accessory, can bring great convenience for the safekeeping and handling.
The mirror can be observed in the power as the optional mirror allows the user to be able to observe without power. In the case of using an external light source, the observed head can be reversed (Puch photoelectric), and slides can be observed through a large hole in the mirror arm.
Personalized design be adjusted for any user, anywhere tilt angle of 30 ° binocular observation tube allows the user to maintain a comfortable position in the observation. The observation tube with interpupillary distance and diopter adjustment function (Puch photoelectric), easy for people to use. Field number 18, high eye point eyepiece design, observers do not have to take off his glasses can be comfortably observed.
CX21 specifications
Project CX21
Optical System UIS2 optical system (infinity corrected system) (Puch photoelectric)
Lighting devices built-in transmitted light, Kohler illumination, 6V20W halogen lamp 100-240V 50/60Hz universal
Focus system of vertical movement of the stage, every lap of the coarse stroke 20mm, fine-tune the minimum distance of 2.5 microns
Change the mirror dial fixed 4-hole objective turret (Puch photoelectric)
Observation Tube Binocular tube, the tube inclination of 30 °, interpupillary distance 48-75mm
Upload stage next device wire transmission, the size of 120mm × 132mm, the scope of activities for the X axis 76mm, Y axial 30mm monolithic specimens folder (the Puch photoelectric)
Abbe condenser, condenser, numerical aperture of 1.25 (oil immersion), built-in aperture diaphragm (Puch photoelectric)
Objective achromatic 4 × NA0.10 WD 22.0mm10 the × NA0.25 the WD 10.5mm40 the × NA0.65 the WD 0.56mm100 × NA1.25 the WD 0.13mm (optional) (the Puch photoelectric)
Eyepiece (10 ×) as the field number of the FN 18 (mildew treatment) (Puch photoelectric)
Optional mirror, 15 × eyepiece (FN12, mold processing), cable bracket,
Wood storage box {264 (W) x 305 (L) x 474 (H)}, micrometer, the arrow indicator, filter tray, dark-field diaphragm (the Puch photoelectric)
▋ Note: The products are imported products, after the receipt of goods in the courier assistance, open the packaging to check the integrity of the product. |
Admin>>>
You are the 27057 visitor
Copyright © GuangDong ICP No. 10089450, On Haipu He Optoelectronics Technology Co., Ltd. (Jiangxi General Agency) All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 27057 visitor
Copyright © GuangDong ICP No. 10089450, On Haipu He Optoelectronics Technology Co., Ltd. (Jiangxi General Agency) All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility